Short Communication | DOI: https://doi.org/10.31579/2690-1919/087
Tribochemistry Consulting, Salt Lake City, Utah 84117, USA and University of Economy, Biotribology Laboratory, 85-229 Bydgoszcz, Poland.
*Corresponding Author: Zenon Pawlak, Tribochemistry Consulting, Salt Lake City, Utah 84117, USA and University of Economy, Biotribology Laboratory, 85-229 Bydgoszcz, Poland.
Citation: Zenon P, Lipid Translocation (Flip-Flop) As One of the Least Understood Dynamical Processes in Articular Cartilage Membrane. J Clinical Research and Reports, 4(5); DOI:10.31579/2690-1919/087
Copyright: © 2020 Zenon P. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Received: 06 April 2020 | Accepted: 12 June 2020 | Published: 10 July 2020
Keywords: transformation flip-flop; cartilage; wettability; hydrophilic; hydrophobic
The lipids molecules translocation in phospholipid membrane is named the (flip-flop) event. For this purpose, the translocation may take place in vivo with the surface of articular cartilage. Flip-flops are one of the least understood dynamical processes in vivo in cartilage membranes. In this work, we explain the molecular mechanism lipid translocation (flip-flop) in vivo during the drying process cartilage surface. Wettability of cartilage surface vs. drying time was determined. Our findings strongly support the idea that the process of translocation lipid (flip-flop) transformed hydrophilic surface in hydrophobic in dry-air condition for healthy and osteoarthritic cartilage. Such material can be classified cartilage as “smart material” and this fact is poorly known in the literature.
Phospholipids molecules in aqueous media spontaneously arrange into a bilayer on the surface of articular cartilage. The bilayer is held together by hydrophobic interactions between the tails. Phospholipid (PL) bilayers on the surface of articular cartilage provide characteristics that are well adapted to wet and relatively dry conditions. This smart surface characteristic creates a hydrophobic-hydrophilic balance resulting in a functional hydrophilic surface in the intact joint. One of the quantitative indicators of surface tribochemical properties is wettability. This is measured as the contact angle between a drop of water and the reference surface.
Wettability characterizes the surface of various objects, which are generally defined as wettable (highly hydrophilic, q~ 0° to 45°) or non-wettable (highly hydrophobic, q ~ 90° to 180°).
The mechanisms to actively transport lipids across a lipid bilayer using specific membrane are widely recognized [1]. All lipids in biomembranes can move within the bilayer, allowing for membrane fluidity and flexibility. Exchanging places with their neighbors by slow transverse diffusion (see Fig. 1) and fast lateral shift (~ 10-6 sec). Double bonds in unsaturated hydrocarbon chains also tend to increase fluidity of the phospholipid bilayers. This fluidity allows for the spontaneous breaking and reforming of membranes [1, 2]. This is called flip-flop mechanism. Membrane fluidity is enhanced at higher temperatures and is also affected by the composition of the bilayer. The formation of a transient water pore (defect) in the membrane inevitably leads to diffusivetranslocation of lipids through the pore, which is driven by thermal fluctuations (Fig.1] [3].

Fig.1. The motion of phospholipid with lipid bilayer in aqueous solution. Transverse diffusion (flip-flop) is slow (~ 105 sec).
The experimentally observed fact that the exposure of lipid membranes to electric field pulses considerably reduces the time required for lipid flip-flops. Negatively charged surface of articular cartilage membrane inevitably leads to diffusive translocation of lipid flip-flop.
In this work, wettability of cartilage surface vs. drying time was determined. Wettability helps us to explain the molecular mechanism lipid translocation (flip-flop) for healthy and osteoarthritic cartilage. Lipid translocation in cartilage membranes is still far from being understood and characterized. It is observed that lipid flip-flop is affected by dehydration activated process. Moreover, we report for the first time wettability of unhealthy cartilage in vivo changes own characteristics.
Experimental
In the delipidization procedure a Folch reagent (2:1 v/v mixture of chloroform and methanol) was used to gradually remove the PL bilayers from the bovine cartilage surface. The samples were immersed in the reagent mixture for 3, 9 and 19 minutes at the same meniscus. After extraction, the sample was placed in saline solution for 1 hour to remove the residual solvent and promote rehydration and then air-dried. These samples were used for the surface wettability and friction measurements. The delipidization procedure removed most of the PL, although some amount of a hydrophobic proteolipid remained as a minor component [4].
Contact angle measurements The contact angle between the liquid and the tested cartilage was measured using a KSV CAM100 tensiometer. A tensiometer is a device for measuring the surface tension of a liquid. The contact angle measured was that between a droplet of a 0.15M saline solution and a given air-dry cartilage surface. The contact angle measurements of the normal (intact) and the delipidated cartilage samples were carried out under dry-air atmosphere in the laboratory [5, 6] at ambient temperature of 22oC and a relative humidity (HR) of approximately 45 %. Five tests were performed on each specimen and each set-up. The contact angle test performed on the normal, partial and completely depleted cartilage samples. The depleted cartilage samples imitate osteoarthritic degradation of cartilage surface.
Formation of structural defects (water pore) is the result of an increase in the lateral surface tension induced by the evaporation surface water. This surface tension produced by formation of a transient water dehydration in the membrane inevitably leads to diffusivetranslocation of lipids (flip-flop) can in turn induce changes from bilayer to monolayer (Fig. 2). A change in surface energy leads to conformational changes in the surface of bovine patella from bilayer (super hydrophilic ~0o contact angle) to monolayer (hydrophobic ~104o). Changes of the wettability contact angle as a function of air-drying time are shown in Fig.2 (c) with totally depleted surface of phospholipid bilayer curve (1) contact angle of 40o; partially depleted PL curve (2) and (3) contact angle of 63o, and 75o, and curve (4) normal articular surface; contact angle of 104o.

Fig. 2. (a) Superficial phospholipid bilayer of articular cartilage in water (Aw) and (b) air-dry (Aa) conditions. (c) Changes of the wettability contact angle as a function of air-drying time. Curve: (1) After a 19-min delipidization in (chloroform/methanol) (2:1, v/v), contact angle of 40o ; (2) after 9 min delipidization, contact angle of 63o , after 3 min delipidization, contact angle of 75o , (4) normal articular surface; contact angle of 104 o . Contact angle SD (n = 5, error bars = 95% confidence limit).

Fig. 3. Phospholipidic bilayers of articular cartilage under the wet and air-dry conditions. Variations in surface energy lead to conformational transformations in the surface phospholipids from bilayer (hydrophilic) to monolayer (hydrophobic). Book cover “Articular cartilage: Lamellarrepulsive lubrication of natural joints” [6].
The wetting studies on healthy cartilage and osteoarthritic surface in vivo indicate that, when exposed to dry atmospheric conditions, only hydrophobic chain is exposed to the outside. When the surfaces are becoming exposed to bulk water the surfaces rapidly become hydrophilic (Fig. 2). These findings are entirely consistent with those of the adhesion measurements [7, 8 ].
We studied how the wetting properties of the cartilage surface in vivo changed with dehydration. The results are described and summarized in Fig. 2. It has been demonstrated that the “smart surface” of cartilage is super hydrophilic when wet and hydrophobic when air-dry, Fig.3. The key to understanding the mechanism of joint lubrication lies in obtaining an insight into the relationships between the structure and function of surface. The main result of the present study is the observation that the rate of lipid flip-flops is significantly enhanced by the spontaneous formation of water pores during dehydration. Evidently, one should then ask whether the rate of pore formation is comparable to the lipid flip-flop rate in the absence of pores. It is observed that lipid flip-flop is affected by dehydration activated processes.
Dear Editorial Team, Clinical Medical Reviews and Reports. My experience with the journal was highly positive. The peer-review process was rigorous, constructive, and completed in a timely manner. The reviewers provided valuable comments that helped improve the quality and clarity of our manuscript. The editorial office was professional, responsive, and supportive throughout all stages of the publication process. Communication was clear and efficient, and any questions were addressed promptly. Overall, I found the journal to maintain high scientific standards and an excellent publication workflow. I would be pleased to consider submitting future work to this journal. Best wishes from, Elena Popa.
It was my pleasure to submit my testimonial concerning the Reviewer Board of our Scientific Journal “Brain and Neurological Disorders”. The Reviewers focused on some modifications and their contribution was helpful. The ladies of our Editorial Office were also supported my efforts. It was my honor to have such a co-operation and I am looking forward for more collaboration.
Dear Grace Pierce, Editorial Coordinator of Journal of Clinical Research and Reports, Thank you for the speedy and efficient peer review process. I appreciate the fact that your peer reviewers do not take months to respond like with some other journals. I would also like to thank the editorial office for responding quickly to my questions. It is an excellent journal. I plan to submit more manuscripts in the future. Best wishes from, Robert W. McGee
Dear Grace Pierce, Editorial Coordinator of Journal of Clinical Research and Reports, Working with you and your team on our recent publication in JCRR has been a truly wonderful and enjoyable experience. The responses were prompt, and the reviewers were patient, constructive, and highly professional. One reviewer in particular gave me the feeling that a professor was carefully reading and commenting on my coursework, which was deeply touching. The entire process was straightforward and hassle‑free, with no tedious online forms to complete. I highly recommend this journal. Best wishes from, DR Aibing Rao, Head of R&D
I Appreciate the Opportunity to Share my Experience with the Journal of Clinical Research and Reports. The peer review process was timely and constructive, and the feedback provided helped improve the quality of our manuscript. The editorial office was professional, responsive, and supportive throughout the process, ensuring smooth communication and efficient handling of the submission. Overall, it was a positive experience collaborating with your team.
Dear Mercy Grace, Editorial Coordinator of Obstetrics Gynecology and Reproductive Sciences, We would like to express our gratitude for your help at all stages of publishing and editing the article. The editors of the magazine answer all the necessary questions and help at every stage. We will definitely continue to cooperate and publish other works in the Obstetrics Gynecology and Reproductive Sciences! Best wishes from, Alla Konstantinovna Politova,